youvee® is new and different than comparable systems. It was developed by engineers with research and industrial experience in the fields of ventilation technology, architecture, optics and series production as part of a special initiative. The impetus came from demands from science and politics for quickly installable air cleaning systems with new, uncritical flow effects and high disinfection performance.
Technical Data
Data | Value |
---|---|
Height | 210 cm |
Durchmesser | 32 cm |
Weight | 15 kg |
Max. volume flow | 835 m3/h |
Max. sound power level | 57 db(A) |
Max. electrical power | 155 Watt |
Electricity costs at 10 hours per day, 300 days per year and an electricity price of 0.25 €Cts/kWh: | 116 €/ per year |
Steuerung | WLAN / BT APP |
Schallentwicklung
Schallwerte und Luftvolumenstrom geprüft durch
HLK-Stuttgart GmbH | www.hlk-stuttgart.de
UVC radiation and the coronavirus
How much UVC energy is needed to neutralize coronaviruses?
Seit Entstehen der Corona Epidemie haben zahlreiche Forscher aus dem Bereich der Medizintechnik und Virologie Messungen durchgeführt, wieviel UVC-Energie zu deren Neutralisierung benötigt wird. Einen Überblick über den aktuellen Stand der wissenschaftlichen Erkenntnis gibt die the publication of the Institute of Medical Engineering and Mechatronics der Universität Ulm, die von der Deutschen Gesellschaft für Krankenhaushygiene veröffentlicht wurde.
Der konservativste Wert um 90% aller Coronaviren zu deaktivieren beträgt 0,66 Milli Joule UVC-Energie pro Quadratzentimeter. Aus diesem Wert kann hochgerechnet werden, dass 1,98 mJ/cm² erforderlich wären, um 99.9% der an Aerosolen anhaftenden Coronaviren zu deaktivieren.
How much UVC energy does youvee® produce?
The UVC radiant power developed inside a youvee® has been determined using computer calculation programs. At maximum volume flow, the dwell time of viruses in the UVC radiation zone is 0.17 seconds. Corona viruses absorb an energy quantity in the area-related average of more than 4mJ/cm2 (25.8mJ/SQ IN). This is twice as much as would be necessary to neutralize 99.9% of corona viruses.